CALIBRATION LABORATORY

Particle counter and photometer calibration

Metrological traceability for your measurements

Particle counter calibration over the 0.1–10 µm range and calibration of aerosol photometers (nephelometers).

Oscilloscope and airborne particle counter during calibration in the LABOX laboratory

Comparison with a reference standard

Particle counter calibration

0.1–10 µm range

Calibration within the particle counter’s range

Metrological traceability

Reference materials and calibrated measurement standards

Evaluated uncertainty

Calibration uncertainty evaluated to EA-4/02

PARTICLE COUNTERS AND AEROSOL PHOTOMETERS

Calibration tailored to the instrument and application

We calibrate instruments used for air cleanliness assessment and filtration testing. Expand the sections for technical details of each procedure.

Particle counter calibration

Comparison of the working instrument with a reference particle counter.

  • Comparison of particle size and count
  • Direct comparison with a primary reference standard
  • Verification of flow rate, sampling time and counting efficiency
  • Calibration range of 0.1–10 µm, depending on the instrument
Calibration details

We compare the instrument’s readings with those of a reference particle counter while measuring a polydisperse aerosol. The reference counter has a valid primary calibration traceable to certified PSL particles.

The laboratory SOP is based on the relative comparison method in JIS B 9921:1997, Annex 2, and selected parts of ISO 21501-4:2018: airflow rate, sampling time and counting efficiency. This is a defined comparative procedure; scope is agreed according to the instrument and intended use.

Aerosol photometer calibration

Calibration of nephelometers used to measure aerosol penetration through filters and test their integrity.

  • A precisely defined challenge aerosol
  • Direct comparison with a primary reference standard
Calibration details

Aerosol photometers, also known as nephelometers, evaluate light scattered by a population of particles. They are used primarily to measure aerosol penetration through filtration systems and detect leaks.

Calibration is carried out by direct comparison with a primary reference standard using a defined challenge aerosol. We agree the scope according to the instrument type.

FROM YOUR BRIEF TO THE RESULTS

How calibration works

Define the instrument

Send the manufacturer, model, measuring range and required date. We will agree a suitable method and scope.

Prepare the calibration

We check the instrument’s technical condition and the availability of the required manuals, software and accessories.

Carry out the comparison

We use the appropriate reference materials or measurement standard and evaluate results, including uncertainty.

Deliver documentation

You receive a calibration certificate with the agreed scope of results. We discuss any further steps.

BEFORE HANDING OVER THE INSTRUMENT

What we will need from you

  • Manufacturer, instrument model and measuring range
  • Intended use and required calibration scope
  • The instrument in good technical condition, with required accessories
  • Technical manual; depending on the adjustment procedure, a service manual and appropriate software

We recommend placing your order and booking calibration at least one month in advance. We also confirm feasibility, availability of the required documentation and access to instrument settings beforehand.

RESULTS AND METROLOGICAL TRACEABILITY

Results with evaluated uncertainty

Calibration results include uncertainty evaluation to EA-4/02. We agree the documentation scope and method according to the instrument.

Particle counters are compared with a reference particle counter with a valid primary calibration. Aerosol photometers are calibrated by direct comparison with a primary reference standard.

Calibration standards and methods

ISO 21501-4 describes calibration and verification of light-scattering airborne particle counters. The published edition is ISO 21501-4:2018 with Amendment 1:2023. Calibration scope is defined according to the instrument and the laboratory SOP.

JIS B 9921:1997, Annex 2 provides the methodological basis for relative comparison in particle counter calibration; this historical reference is retained to identify the method used.

EA-4/02 sets out procedures for evaluating measurement uncertainty in calibration.

BEFORE YOU ORDER

Frequently asked questions

How do you calibrate particle counters?

We calibrate particle counters by comparing your instrument’s readings with those of a reference particle counter with a valid primary calibration. The offered particle size range is 0.1–10 µm; the specific range is agreed according to the instrument.

LET’S START WITH YOUR INSTRUMENT

Need calibration?

Send us the instrument model and required date. Together, we will define calibration options and scope.