CALIBRATION LABORATORY
Particle counter and photometer calibration
Metrological traceability for your measurements
Particle counter calibration over the 0.1–10 µm range and calibration of aerosol photometers (nephelometers).

Comparison with a reference standard
Particle counter calibration
0.1–10 µm range
Calibration within the particle counter’s range
Metrological traceability
Reference materials and calibrated measurement standards
Evaluated uncertainty
Calibration uncertainty evaluated to EA-4/02
PARTICLE COUNTERS AND AEROSOL PHOTOMETERS
Calibration tailored to the instrument and application
We calibrate instruments used for air cleanliness assessment and filtration testing. Expand the sections for technical details of each procedure.
Particle counter calibration
Comparison of the working instrument with a reference particle counter.
- Comparison of particle size and count
- Direct comparison with a primary reference standard
- Verification of flow rate, sampling time and counting efficiency
- Calibration range of 0.1–10 µm, depending on the instrument
We compare the instrument’s readings with those of a reference particle counter while measuring a polydisperse aerosol. The reference counter has a valid primary calibration traceable to certified PSL particles.
The laboratory SOP is based on the relative comparison method in JIS B 9921:1997, Annex 2, and selected parts of ISO 21501-4:2018: airflow rate, sampling time and counting efficiency. This is a defined comparative procedure; scope is agreed according to the instrument and intended use.
Aerosol photometer calibration
Calibration of nephelometers used to measure aerosol penetration through filters and test their integrity.
- A precisely defined challenge aerosol
- Direct comparison with a primary reference standard
Aerosol photometers, also known as nephelometers, evaluate light scattered by a population of particles. They are used primarily to measure aerosol penetration through filtration systems and detect leaks.
Calibration is carried out by direct comparison with a primary reference standard using a defined challenge aerosol. We agree the scope according to the instrument type.
FROM YOUR BRIEF TO THE RESULTS
How calibration works
Define the instrument
Send the manufacturer, model, measuring range and required date. We will agree a suitable method and scope.
Prepare the calibration
We check the instrument’s technical condition and the availability of the required manuals, software and accessories.
Carry out the comparison
We use the appropriate reference materials or measurement standard and evaluate results, including uncertainty.
Deliver documentation
You receive a calibration certificate with the agreed scope of results. We discuss any further steps.
BEFORE HANDING OVER THE INSTRUMENT
What we will need from you
- Manufacturer, instrument model and measuring range
- Intended use and required calibration scope
- The instrument in good technical condition, with required accessories
- Technical manual; depending on the adjustment procedure, a service manual and appropriate software
We recommend placing your order and booking calibration at least one month in advance. We also confirm feasibility, availability of the required documentation and access to instrument settings beforehand.
RESULTS AND METROLOGICAL TRACEABILITY
Results with evaluated uncertainty
Calibration results include uncertainty evaluation to EA-4/02. We agree the documentation scope and method according to the instrument.
Particle counters are compared with a reference particle counter with a valid primary calibration. Aerosol photometers are calibrated by direct comparison with a primary reference standard.
ISO 21501-4 describes calibration and verification of light-scattering airborne particle counters. The published edition is ISO 21501-4:2018 with Amendment 1:2023. Calibration scope is defined according to the instrument and the laboratory SOP.
JIS B 9921:1997, Annex 2 provides the methodological basis for relative comparison in particle counter calibration; this historical reference is retained to identify the method used.
EA-4/02 sets out procedures for evaluating measurement uncertainty in calibration.
BEFORE YOU ORDER
Frequently asked questions
We calibrate particle counters by comparing your instrument’s readings with those of a reference particle counter with a valid primary calibration. The offered particle size range is 0.1–10 µm; the specific range is agreed according to the instrument.
LET’S START WITH YOUR INSTRUMENT
Need calibration?
Send us the instrument model and required date. Together, we will define calibration options and scope.