LABOXCleanroom technology.
From design to long-term support.

ACCREDITED TESTING LABORATORY

Cleanroom testing, qualification and validation

Results you can rely on

We carry out qualification testing and validation of cleanrooms, laminar flow cabinets and safety cabinets. We also verify laboratory equipment, HVAC systems, thermal processes and other systems and equipment.

ČIA and ILAC MRA accreditation marks

LABOX testing laboratory No. 1313 is accredited by the Czech Accreditation Institute for testing rooms and equipment with controlled air cleanliness, HVAC systems and components, microclimate, the working environment, thermal processes and air filtration equipment. The laboratory is accredited to ČSN EN ISO/IEC 17025, the Czech adoption of EN ISO/IEC 17025.

Technician measuring air velocity with a horizontal probe beneath a HEPA filter

Confidence in the results

Verified procedures and metrological traceability

International recognition

Accredited results under international recognition arrangements

Speed and efficiency

Parallel testing of equipment and shorter shutdowns

An experienced team

More than 2,000 qualification tests and validations every year

CLEANROOMS AND PROCESS EQUIPMENT

What do you need to verify?

We define testing and validation scope according to the facility’s purpose, equipment type and required parameters. We test new technology and verify modifications and conditions during routine operation.

Parallel testing, shorter shutdowns

We are among the largest testing laboratories in Europe. Our team and equipment enable us to test several units in parallel and limit disruption to your operation.

Cleanrooms

Cleanrooms for pharmaceutical manufacture and preparation, operating theatres, PET centre cleanrooms, laboratories, pharmacies and other facilities with controlled air cleanliness.

Laminar flow cabinets

Laminar flow cabinets, microbiological safety cabinets (biohazard cabinets), clean booths, isolators and fume cupboards.

HVAC systems

HVAC systems and filtration stations with high-efficiency particulate air filters and iodine filters.

Sterilisation equipment

Steam and dry-heat sterilisers, autoclaves and sterilisation tunnels.

Temperature-controlled and process equipment

Incubators, thermostatic equipment, refrigerators, freezers, cryogenic equipment, stability chambers, temperature-controlled storage, heated surfaces, freeze dryers and fermenters.

Other production and laboratory equipment

Centrifuges, decontamination systems, compressed air, differential pressure gauges, cleanroom garments and continuous environmental monitoring systems (EMS).

Unsure which tests you need?

Can’t find your equipment in the list, or unsure which tests are appropriate? Describe the equipment and the purpose of verification. Together, we will assess testing options, define the scope and agree a suitable date.

MEASURED PARAMETERS AND TESTS

Measured parameters

These tests cover cleanrooms, laboratory and process equipment, and specialist applications such as filtration systems in nuclear power plants.

  • Microclimatic parameters: temperature, humidity, air velocity and barometric pressure
  • Indoor air parameters: airborne aerosol concentration and cleanroom air cleanliness classification
  • HVAC parameters: air velocity, volumetric airflow rate, temperature, relative humidity, pressure, ductwork and equipment leakage, and airflow visualisation (smoke studies)
  • Filtration efficiency: overall and fractional efficiency of high-efficiency filters, filtration equipment and filter media
  • Thermal processes: temperature, pressure, heat distribution and heat penetration
  • Microbiology: air and water contamination, swabs, settle plates, active air sampling and strain identification
  • Other parameters: CO2 concentration, conductivity of demineralised and purified water, and rotational speed

FROM YOUR BRIEF TO THE RESULTS

How testing and validation work

Agree the brief

We define the room or equipment, the purpose of verification, documentation and required dates.

Prepare the scope

We prepare a qualification protocol covering measured parameters, sampling plans, test conditions and acceptance criteria.

Carry out testing

We verify the agreed parameters with regard to equipment status and operating conditions.

Deliver documentation

We evaluate the results and deliver a qualification report. We agree any further verification, requalification or revalidation required.

QUALIFICATION AND VALIDATION DOCUMENTATION

From installation checks to process verification

We provide individual qualification stages and coordinate their interfaces according to the project. Documentation follows GMP requirements and ALCOA+ data integrity principles, including protocols and a final evaluation in the qualification report.

Standards and methods for the technology

Depending on the test subject and agreed scope, we use the relevant parts of ISO 14644, EN 12469 and related EN ISO standards for sterilisation and thermal processes. For pharmaceutical facilities, we consider GMP, EU GMP Annex 1 and Annex 15. For projects subject to Czech requirements, this also includes applicable SÚKL guidance, notably VYR-32 and its relevant annexes, LEK-17, version 1 for sterile medicinal product preparation in pharmacies and healthcare facilities, and DIS-15, version 4 for temperature monitoring and control during medicinal product storage and transport.

Depending on the application, we also refer to IES recommendations, FDA / cGMP, requirements for medicinal product preparation in healthcare and ISO 13485 quality management requirements. The applicable standard edition and procedure are defined for the equipment and purpose of verification.

Historical references VYR-34 and VYR-36: clients still use these terms for verification of thermal sterilisation processes and cleanrooms. These Czech SÚKL guidelines have been withdrawn; current testing and assessment follow the applicable standards and methods for the technology and purpose of verification.

Historical reports may also refer to FS 209E. We use the relevant parts of ISO 14644 for current cleanroom classification.

  • DQ – Design Qualification: assessment of the design against defined requirements
  • IQ – Installation Qualification: verification of installation and documentation
  • OQ – Operational Qualification: verification of function under defined conditions
  • PQ – Performance Qualification: verification of performance during intended operation
  • Periodic monitoring: testing between validation activities to verify that selected parameters remain within the expected tolerances

BEFORE YOU ORDER

Frequently asked questions

What are the benefits of an accredited laboratory?

Accreditation demonstrates the laboratory’s technical competence and independent assessment of its testing procedures.

  • Confidence in the results: regularly assessed procedures and laboratory quality management.
  • Metrological traceability: measuring equipment traceable to the relevant measurement standards.
  • International recognition: accredited test results under mutual recognition arrangements for accreditation.

View the accreditation certificate (PDF) ↗

LET’S START WITH YOUR OPERATION

Which parameters do you need to document?

Let’s discuss your cleanroom, laboratory equipment or complete process system. We will propose an appropriate testing scope and next steps.